Phys. Rev. A 62, 013404 (2000) [5 pages]Measuring the capture velocity of atoms in a magneto-optical trap as a function of laser intensityReceived 2 September 1999; published 9 June 2000 Using the dark-spot Zeeman-tuned slowing technique, we have measured the capture velocity of a magneto-optical trap as a function of the trap laser intensity. The values obtained are in reasonable agreement with calculations based on a simple model. Nevertheless, the dependence of capture velocity in the low-intensity regime seems to be slightly different from the predictions. The measurement of this type of trap parameter is of interest in the analysis of exoergic cold collisions, where the knowledge of such values is important for the interpretation of experimental results. © 2000 The American Physical Society URL:
http://link.aps.org/doi/10.1103/PhysRevA.62.013404
DOI:
10.1103/PhysRevA.62.013404
PACS:
32.80.Pj, 33.80.Ps, 34.50.Rk
|